STANDARD CAPACITORS
Compressed gas insulated high precision capacitors for C/tan delta measurement, or very accurate voltage measurement
APPLICATION
Gas insulated standard capacitors are used for high voltage measurements of capacitance and loss factor, as a reference normal. They can also be used as a very accurate HV section of a capacitive voltage divider. The standard version is for indoor use, however a special outdoor design is available upon request. Mohaupt standard capacitors can be used in combination with any kind of modern loss factor measurement equipment.
BENEFITS
- Extremely low loss factor and high stability of capacitance
- Unaffected by external field influences (proximity effects)
- Excellent voltage performance even under high humidity conditions
- Calibration at certified laboratory available upon request
TECHNICAL DATA
| Type | Max. Voltage (kV) | Capacitance (pF) | Loss factor | Partial discharge level at Un (pC) | Impulse test voltage 1.2/50 µs (kV) |
|---|---|---|---|---|---|
| NK 200 | 200 | 100 | 400 | ||
| NK 300 | 300 | 50 | 600 | ||
| NK 400 | 400 | 50 ± 0.25 | 800 | ||
| NK 600 | 600 | 33.3 ± 0.2 | 1200 | ||
| NK 800 | 800 | 25 | 1600 | ||
| NK 1000 | 1000 | 20 | 2000 | ||
| NK 1200 | 1200 | 20 | 2400 |